Gas Chromatographs

  Sample Injection Port

Split/splitless

 

  • For capillary column

  • Independent control of column inlet pressure and split flow rate by original digital controller.

  • Automated control by only setting column flow rate and split ratio.

  • Setting range for split ratio:0~300(max)

  • Maximum setting pressure: 500 kpa

Direct injection

 

  • Injection by wide-bore column

Packed column

  • Digital flow rate control and setting flow rate range: 0~100ml/min 

  • Injection system either packed or capillary column is determined at factory shipped level

  • PTV for capillary, on-column injection system(option)

  Detectors

Flame Ionization Detector (FID)

  • Minimum amount of detection: 2x1012g/s

  • Temp range:  ambient ~ 400 C

  • Dynamic range 107

  • Standard installation for flame monitor and auto-ignition function

  • Auto-digital-zero correction function

Thermal Conductivity Detector (TCD)

  • Sensitivity: H2 0.5 ppm(as career gas)

  • Temp range:  ambient ~ 400 C

  • Dynamic range 104

  • Auto-digital-zero correction function

  • Digital signal output

  • Precise digital temp. control

  • Filament protection function

Electron Capture Detector (ECD)

  • Minimum amount of detection:Ύ-BHC, 1x10-13 g

  • Temp range:  ambient ~ 350 C

  • Dynamic range 104

  • ECD with display

  • Originally developed less-bleed line source: clean ECD

 

 

 
Gas Measuring Systems
   
 
  • Trace Impurity in O₂ Measuring System

  • Trace Impurity in AIR Measuring System

  • Trace Impurity in Semiconductor Measuring System

  • Trace Impurity in CO Measuring System

  • Trace Impurity in Ar and N₂ Measuring System

  • Trace Impurity in N₂ Measuring System

  • S Compound in Liquid CO₂ Measuring System

  • Mixed Gas Measuring System

  • VOC in Air Measuring System

  • Fuel Cell Gas Measuring System

  • Catalyst Evaluation Gas Measuring System

  • Sealed Chamber Leakage Measuring System

  • Trace Total Sulfur Measuring System GTS-201

  • Oil in Liquid CO₂ Measuring System GAL-202

  • Lamp Gas Measuring System

  • Hydrogen Gas Measuring System

  • Trace Component in H₂ or He Concentration Measuring System

  • Trichloroethylene in Air Monitoring System JTM-101

  • VOC Measuring System (P & T Method)

 
 

 
 
Gas Sampler and Other Products
   
 
  • Gas 1000 Series/Automatic Gas Sampler

  • Gas 1000 Series/Manual Gas Sampler

  • Offensive Odor Sample Pretreatment Unit

  • EOG Densitometer GC-216

  • Pyrolysis and Hydrogen Addition Unit

  • Methane Convertor

  • D/A Convertor

  • Flame-out Detector (control unit)

  • Automatic Gas Sampler

  • Manual Gas Sampler

  • Automatic Heat Reserving Gas Sampler

  • Manual Heat Reserving Gas Sampler

  • Aging Unit AGI-201

  • LPG Vaporizer LSV-202

  • Flow Channel Switching Control Unit

  • Flow Channel Switching Control Panel

 
 

     
 
Gas Analyzer Instruments
 
 

 
 

 

 

- GAS ANALYZER INSTRUMENTS -

  1. Gas Analyzers 2. Organic Element Analyzer product Guide
 
  • Online Underwater VOC Analyzer JVM-103

  • Medical Gas Analyzer GC-202

  • Automatic Medical Gas Analyzer GC-202A

  • Total Hydrocarbon Analyzer THC-201

  • Automatic Fuel Gas Analyzer GC-2011

  • Trace Gas Analyzer TGA-201

  • Diffusive Hydrogen Analyzer GC-206

 

  • Micro Corder JM 10, JM 1000HCN, JM 010-JM 012

  • Macro Corder JM 1000CN, JM 1000HC, JM 3000CN

  • Protein Corder JM 3000N

  • S Micro Corder JMS 10-JMS 12

  • Oxygen Analysis Kit JMOK 10

  • Liquid Sample Sealer JMLS 10

  • Reduction Unit JMR 10-JMR 20

  • S Corder unit JMSU 10

 

                  3. Analyzer Instruments for Environmental Pollution
 
  • Automatic NOx/O₂ Analyzer

  • Automatic CO/CO₂ Analyzer

  • Automatic Stack Gas Analyzer

  • Automatic VOC Monitor

  • Automatic THC Analyzer

  • Automatic NO/NO₂/NOx Analyzer

  • Automatic Ethylene Analyzer

  • Automatic NO/NO₂/ NOx Analyzer

  • Drain Point

  • Main Conditioning Tank System

  • Automatic Water Quality monitoring System

  • K82S Automatic Water Quality monitoring System

  • Automatic Code Analyzer

  • Automatic UV Spectrophotometer

  • Automatic TOC Analyzer

  • Automatic Total Nitrogen Analyzer

  • Automatic Total Phosphorus Analyzer

  • Automatic Phosphorus ION Analyzer

  • Automatic Total Phosphorus/Nitrogen Analyzer

  • Automatic Total Phosphorus Analyzer

  • Automatic Total Nitrogen Analyzer

  • Automatic Phosphorus Cyanogens Analyzer

  • Automatic ION Electrode Monitor

  • Automatic Ammonia Monitor

  • Automatic Fluorine ION Monitor

  • Automatic Mercury Analyzer

  • Automatic Manganese Analyzer

  • Automatic Phenol Analyzer

  • Automatic Phenol Analyzer

  • Automatic Formaldehyde Analyzer

  • Automatic Thiocyanogen Analyzer

  • Automatic Hexavalent Chromium Analyzer

  • Automatic Total Chrome Analyzer

  • Automatic Suspended Solid Analyzer

  • Automatic Hydrogen peroxide Analyzer

  • Automatic Chlorite Analyzer

  • Automatic SVI Monitor

  • Process Polar graphic  Analyzer

  • Water Pollution Load Calculation

  • Multi Sampling System

  • Automatic Abnormal Value Sample Collector

  • Automatic Total Nitrogen Analyzer

  • Automatic TOC Analyzer

  • Halogen Sulfur measurement System

  • Micro Melting point System

  • Micro Melting Point Meter

  • Osmometer/Vapor Pressure Osmometer

  • Polar graph System

  • Potentio/Galvanostatic Electrolyzer

  • Electrolyzer Analyzer

 

   